Form I-RA/D 140/235 (Version A), Mfg No. 110318 Rev 3, Page 27
Cleaning Combustion Chamber, Heat
Exchanger and Flue Pipe
WARNING: Used oils may contain engine-wear metal
compounds and foreign materials. When burned, these
compounds are deposited within or exhausted from this
heater. Therefore, care should be taken when using,
cleaning and maintaining this equipment.
Whenever any cleaning including the flue pipe and exhaust stack is done,
proper protective equipment, including gloves and a face mask or respira-
tor, must be worn.
WARNING: Turn off electric power before inspecting or
cleaning the unit. Allow unit to cool.
Inspection
Maintenance
Continued
To determine need for cleaning, inspect the heat exchanger tubes through
the access door on the end of the heater opposite the burner.
Remove the door panel by lifting upward and outward on the door
handle.
Using a 1/2” wrench, remove the nuts and washers from the inner
turning box door.
Pull the door directly off the studs.
Shine a flashlight into the heat exchanger.
If tubes are 25% blocked, leave covers off and
proceed with cleaning.
NOTE: You cannot adequately make this determination
through the flame observation door. The majority of the
settlement of ash accumulates in the heat exchanger tubes.
View with
the Outer
Access Door
Removed